Containerized BESS
Liquid-cooled BESS container integrating PV input, diesel generator interface, utility grid interface, battery storage, EMS, BMS, PCS, ATS, STS, MPPT and fire protection in one microgrid cabin.
AINEGY Containerized BESS is designed for commercial, industrial, remote and weak-grid projects that need more than a battery container. The system coordinates solar power, battery storage, diesel generator backup and utility grid input through EMS control, fast source switching, liquid cooling and integrated fire protection.

Containerized BESS Models
AINEGY BESS containers are configured for solar-diesel-grid microgrid projects, combining battery storage, power conversion, source switching, fire protection and outdoor liquid cooling in a transportable container structure.

250kW/522kWh Solar-Diesel Hybrid Microgrid BESS Container
Medium-capacity liquid-cooled BESS container for commercial backup, solar storage, weak-grid and remote microgrid projects.

500kW/1MWh Solar-Diesel BESS Container
Outdoor BESS container for larger C&I sites requiring PV access, diesel generator backup, utility interface and EMS dispatch.

500kW-1MW Microgrid BESS Container Series
High-capacity BESS container series for larger microgrid, industrial backup and multi-container energy storage projects.
Integrated Microgrid Architecture
This containerized BESS is a solar-diesel-grid microgrid all-in-one cabin. It integrates power generation access, battery storage, power conversion, source switching, fire protection and energy management into one factory-integrated system.

How the Microgrid Cabin Operates
The system is designed to keep loads supplied by coordinating PV generation, battery storage, diesel generator backup and utility grid input. EMS monitors load demand, battery SOC, PV output, grid status and generator status to select the operating strategy.
Power Source Switching Logic
The system supports source coordination between PV, battery, diesel generator and utility grid. Switching strategy is selected according to project load type, backup requirement, power quality and site operating mode.
EMS Control Strategy
EMS is the control center of the microgrid BESS container. It collects operating data from PV, battery, PCS, generator, grid interface, ATS, STS and loads, then dispatches energy according to priority, safety and project strategy.


Fire Protection, Cooling and Safety
Fire protection is a core part of the containerized BESS design. AINEGY integrates fire protection with BMS monitoring, liquid cooling, electrical protection, alarms and system control logic to support safer outdoor battery energy storage deployment.
Choose by Project Scale
BESS container selection depends on load power, battery capacity, PV capacity, diesel generator strategy, utility grid condition, backup duration, switching requirement and fire safety standard.
Typical Applications
AINEGY containerized BESS is suitable for projects where battery storage must work together with solar power, diesel generator backup, utility grid input and microgrid control.
Configuration Factors
BESS container price and technical configuration depend on power rating, battery capacity, PV input, diesel generator interface, grid connection, ATS/STS switching, cooling method, fire protection and project safety requirements.